Dear Mr.Nisarg Kedar,

Why it is not a good engineering practice?

Is there any technical reason for the same or code restricts the same?

Regards,

Hareesh K V

On Nov 22, 2017 5:12 PM, "NISARG KEDAR" <nisarg.tuv@gmail.com> wrote:
It's not a good engineering practice

On Nov 20, 2017 11:24 AM, "Hareesh K V" <hareesh13h@gmail.com> wrote:
Respected Members,

Reference Code: ASME B31.3

Can we take a branch connection from a standard fitting (other than using a O'let)?

eg: one 1/2" tapping from a eccentric reducer of 3"NBX2"NB.

Please guide me with code clause.

Regards,

Hareesh K V
+91-8547859202

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...