Amit just to add more.
E6013 is normally used in structural applications.
Also check the
1. Carbon Equivalent and the required Preheat which has to be used during tacking.
2. Check the thickness and the resultant restraint and the applicable preheat.
Thanks & Regards
J.Gerald Jayakumar
0091-9344954677
On Saturday, November 25, 2017, 8:13:54 PM GMT+4, Amit Singh <amit086@gmail.com> wrote:
Dear Experts,
-- One of my customer is using our E6013 electrode which is highly cellulosic.
He has observed crack after tack welding.
Need some solution for this problem.
Thank you in advance.
Regards,
Amit Singh