Saturday, January 10, 2015

[MW:22695] Crack in fillet weld between Inconel 625 and superduplex steel (25 Cr)

Have you tried to do the root pass with SMAW ENiCrMo3 electrode?

Sergio Muñoz
IWE-IIW
http://Weld-ING.blogspot.com

--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/a45608ef-4773-4f84-9c96-c852a6d884b0%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:34920] Tubesheet Hole step

Hello Team, I have one question any tolerance given for tubesheet Hole step. Please do needful. Regards, AP  -- https://materials-...