Some alloy steels shown better relationship between actual impact properties with lateral expansion instead of joules value of absorbed energy. This has been practiced in papers specially in case of high absorbed energies.
Regards
On Tue, Jan 6, 2015 at 11:27 AM, Saravanan Sornam <saravanshyla@gmail.com> wrote:
Dear Metallurgists ,--Could you please explain that,why lateral expansion value of Min. 0.38 mm given in ASME Sec VIII Div I , UHA-51 for Charpy Impact Tests, instead of Joule Value for High Alloy steels like Duplex, Super Duplex etc.What is the significance of Lateral expansion for such High Alloys.Regards,Saravanan.
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CALV1rkKr_DRJNkPC5H-5Wwj16i0KubE370PKEXtxOrgbdUFBTw%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.
M. Shokri Arfaei
ISA-ISTS - Metallurgy Lab. Manager
ASNT NDT Level III
International Welding Engineer
Tel.: +98 21 66282127
Fax: +98 21 66282779
Mob.:+98 912 1394023
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAC8uMttTQ2C%2BGv0FzD0dZU2x8Ryg1YzZ5ycsO56%3DPNGkvcr%2B9Q%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.
No comments:
Post a Comment