Friday, January 9, 2015

[MW:22692] Flare Bevel Groove Joint

Hi Experts

As per AWS D1.1 2010, whether Flare Bevel Groove Joint is a CJP or PJP?  As per AWS A 2.4, the flare grove joint usually have a symbol of S(E), S represent the Distance of point of tangency to top member and E will be groove weld size. However in the IFC drawing we recieved , does not have any of S(E)?

Can you guys let me know whether it is PJP or CJP? Any clause in AWS or relevant code to support this? 

Attached will be the sketch of drawing. 


Best Regards,
Billy Tan 



No comments:

[MW:34920] Tubesheet Hole step

Hello Team, I have one question any tolerance given for tubesheet Hole step. Please do needful. Regards, AP  -- https://materials-...