Skip to main content

Re: [MW:14967] F.No. for E309MoL

Mr. Jayaraman,

ASME Sec. IX  clearly defines that, 

SFA 5.4 under  F4 are for all the electrodes other than austenitic and duplex. where in,

SFA 5.4 under  F5 are for all the electrodes under austenitic and duplex.

Since your E 309 Mo L is fully austenitic, it is considered under F5 only.

sridhar.


From: GUJULA JAYARAMAN Raju <rajudhanush@gmail.com>
To: materials-welding@googlegroups.com
Sent: Thursday, 26 July 2012 10:17 AM
Subject: [MW:14963] F.No. for E309MoL


I need clear explanation As per ASME Sec IX, F.No. for  E309MoL Electrodes in SFA 5.4.
It is confusing to clearly define the  E309MoL Electrodes as F.No.4 or F.No.5.
So, please anyone can clarify.


Thanks & Regards

Gujula J Raju
QC Supervisor

GIWI SAUDI ARABIA LTD

SAMSUNG SAUDI ARAMCO PROJECT

Shaybah Inlet & Gas Treatment Project PKG#1
Shaybah, Kingdom of Saudi Arabia
Mob: +966 550858370




--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

[MW:30043] Weep hole

If weep hole is not provided in dummy pipe before welding What will happen??? -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/da251ee6-fa7f-4851-b876-cdb3834ae341%40googlegroups.com .

[MW:36169] Cold Bending Qualification

Dear Experts,  Can anyone share the inspection requirements or a qualification procedure for cold bending? Our client spec states only the requirements for induction bending and would like to know your opinion on the cold bend inspection requirements. The code of construction is B31.3, Max. 5D bends, A106 SS 316L.  Thanks in Advance. -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/1be61cc3-e9c9-4a5f-834d-e8485e248432n%40googlegroups.com .