Mr. Jayaraman,
ASME Sec. IX clearly defines that,
SFA 5.4 under F4 are for all the electrodes other than austenitic and duplex. where in,
SFA 5.4 under F5 are for all the electrodes under austenitic and duplex.
Since your E 309 Mo L is fully austenitic, it is considered under F5 only.
sridhar.
From: GUJULA JAYARAMAN Raju <rajudhanush@gmail.com>
To: materials-welding@googlegroups.com
Sent: Thursday, 26 July 2012 10:17 AM
Subject: [MW:14963] F.No. for E309MoL
I need clear explanation As per ASME Sec IX, F.No. for E309MoL Electrodes in SFA 5.4.
It is confusing to clearly define the E309MoL Electrodes as F.No.4 or F.No.5.
So, please anyone can clarify.
Thanks & Regards
Gujula J Raju
QC Supervisor
GIWI SAUDI ARABIA LTD