Saturday, March 31, 2012

Re: [MW:14033] What is acceptance criteria for root undercut

Dear Sajid,

Please find below the attachments from API 1104 for the acceptance criteria for undercut.

Thanks and Regards,

M.SarojKumar
AWS-CWI and ASNT Level-II NDT in RT,UT,PT,MT
Inspection Engineer.

On Fri, Mar 30, 2012 at 9:24 AM, sajid sakhidas <sajidsakhidas@gmail.com> wrote:
Dear sir,

Good morning,

What is acceptance criteria for root ubndercut for flow line and
pipeline(API1104 or ASME B31.4 and B31.8),if possible please give me
refrance.

Thanks

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...