Hi mauricio,
Yes PWHT is required in this case.
Thanks
Ravish
On Tuesday, December 20, 2011 9:06:31 AM UTC+5:30, Raghuram Bathula wrote:
Yes it is required for Thickness > 0.75" (20mm)--On Tue, Dec 20, 2011 at 4:43 AM, mauricio padilla <mauricio_padilla_f@yahoo.com> wrote:
--
Dear,Please I need your Help, about ASME B31,3.I need to know if it is required PWHT.CASE:Pipe A106 Grb (PN 1)wall thickness 0.844"B31.3Chapter VTable 331.1.1According to table 331.1.1 really is it necessay PWHT.Please tell meIs it correct?.Best regardsMauricio
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.