Re: [MW:13948] use of E 7018 -1 & ER 70S-6 to weld SA 516 GR 70 MATERIAL

Dear Asrad Azmi,
Additional to Mr. Arunachalam's comments
 
F7P8 EH12K (P= with PWHT) / essential variables as per QW404.9
 
Kavin Murugam
0126159644

From: Arunachalam A <arunvani@gmail.com>
To: materials-welding@googlegroups.com
Sent: Sunday, March 18, 2012 12:04 AM
Subject: Re: [MW:13913] use of E 7018 -1 & ER 70S-6 to weld SA 516 GR 70 MATERIAL

ER 70-S6 weld metal chemical analysis does not meet A No. 1.  

If you have qualified a WPS with Er 70-S3 etc, then this wire is not acceptable.  ( Manganese content is more than 1.6% in weld metal)

arun

On Sat, Mar 17, 2012 at 12:23 PM, asad azmi <azmiasadayub@gmail.com> wrote:
Dear All,
 
Vessel is being fabricated as per ASME SEC VIII DIV 1.
 
Base material - SA 516 GR 70 HIC - 30 mm Thk. IMPACT TEST not required.
 
  
normally  we are using E 7018 for SMAW,  ER 70S2 for GTAW  & F7P8 EH12K  for SAW Process to weld  above base material.
 
Can we use E7018-1 for SMAW,  ER 70 S6   for GTAW  & F7P8 EH12K for SAW for the above base material.
 
Please Advice.
 
Thanks & Regards
 
Asad Azmi
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
Arunachalam.A,

Give a Man some Money, you make him Beggar for a Day.
Make him live on Welfare schemes, you succeeded in making him Beggar for life.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...