Skip to main content

Re: [MW:13936] WATER QUENCHING OF S.S. PQR

whatis problems to deliverd my mail. previousaly it was ok! then what happen pl gauide
----- Original Message -----

From: Karthik

To: materials-welding@googlegroups.com

Sent: Mon, 19 Mar 2012 13:09:19 +0530 (IST)

Subject: Re: [MW:13925] WATER QUENCHING OF S.S. PQR



Hi,
No need to do quenching. Normally interpass temperature for Austenitic Stainless steel will be 170 degrees maximum. You can monitor the Interpass temperature by Infrared thermometer and if it reach nearer to 170 degrees then stop welding and let it cool down and continue welding. we did like this and we found no defect/problem in PQR.

 
Thanks & Regards,

(Karthik)

Karthikeyan.S
  
QA/QC Manager
  
German-Thai Boiler Engineering Cooperation Limited.
Rayong Factory ;
379 Moo.6 Soi 8, Tambol Pananikom,
Nikompattana, Rayong 21180 THAILAND
Tel : +66 38 897 035-9 Ext. 137
Fax : +66 38 897 034
  
Hand Phone: 0066 892512282

  

  From: CHINTUKUMAR GANDHI <cgandhi1975@yahoo.com>
To: materials-welding@googlegroups.com
Sent: Saturday, March 17, 2012 6:03 PM
Subject: [MW:13910] WATER QUENCHING OF S.S. PQR



Dear Experts,


 


Is it advisable to water quench the Austenitic S.S. PQR (6 mm. Base Metal Thk., SA 240 Tp. 316L) subsequently after each pass and before proceeding for next pass?


 


Same procedure was followed during PQR of 6 mm. to 10 mm. base metal Thk. SA 240 Tp. 304L PQR to control the inter pass temp. max. 100º C. But, unfortunately, the PQR was failed in IGC test as per ASTM A 262 Pr. E. Intermetallic ditches observed in weld metal, and in H.A.Z. and Parent Metal- Ditch structure observed. Also one  root bend was failed in testing. What will be the reason?


 


Which precautions to be taken during qualification of 6 mm. Base Metal Thk., SA 240 Tp. 316L PQR and what will be the qualified max. range of base metal thickness?


 


Please share your experience with me.


 


Thanks & regards,


 


 


C. R. GANDHI


(Welding Engineer) 


 


 


 


 








--


To post to this group, send email to materials-welding@googlegroups.com


To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com


For more options, visit this group's bolg at http://materials-welding.blogspot.com/


The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.




  








--


To post to this group, send email to materials-welding@googlegroups.com


To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com


For more options, visit this group's bolg at http://materials-welding.blogspot.com/


The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

Comments

Popular posts from this blog

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

[MW:5202] RE: 5200] NDT after PWHT

------------------------------------- Interpretation:  I‑89‑14 Subject:         Section I (1986 Edition, 1987 Addenda), PW‑11,                  NDE Prior to PWHT Date Issued:     December 15, 1988 File:            BC88‑393   Question: Does PW‑11 require that NDE be performed on welds after they have been subjected to the postweld heat treatment required by PW‑39?   Reply: No, unless the conditions described in PW‑11.2.2 exist. ---------------------------------------------- Interpretation:  VIII-1-98-09 Subject:         Section VIII, Division 1 (1995 Edition, 1996 Addenda); NDE                 ...

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...