Dear Azad
It is unsafe to do like that
Can you please tell me is that on the top of flange is vent for the pressure gauge and welded to the top plate. If yes and the the plates are only welded on the edge as I understand from the figure the pressure is on the thinnest plate will be the same as on the thickest which is totally unsafe. I am totally agrees with M.Vijayan the welding of both plates should be layered as per ULW-17(g) and fig ULW 17.4 of ASME Sec VIII, Div.1. but in that case also u canot put the vent on the top.
With Kind Regards,
Chandrakant Yadav
With Kind Regards,
Chandrakant Yadav
LINDE PROCESS PLANT (SOUTH AFRICA)
--