Dear Karthik :
I have a complicated situation with pressure gauge calibration period.
During calibration test, our gauge found to be showing wrong reading (below actual). And clients ask to re-test all spool pipe tested using the gauge.
My question, is that acceptable ? luckily there are only small number of spool to be re-tested, but I cant imagine if that happens to spools that already put in service.re
Just a share, but I appreciate any coments and advise.
Best Regards
Bonardo
I have a complicated situation with pressure gauge calibration period.
During calibration test, our gauge found to be showing wrong reading (below actual). And clients ask to re-test all spool pipe tested using the gauge.
My question, is that acceptable ? luckily there are only small number of spool to be re-tested, but I cant imagine if that happens to spools that already put in service.re
Just a share, but I appreciate any coments and advise.
Best Regards
Bonardo
From: Karthik <karthik6684@yahoo.com>
To: materials-welding@googlegroups.com
Sent: Thu, 25 November, 2010 2:13:24 PM
Subject: Re: [MW:8373] Hydrotesting Pressure gauge calibration
Hi, Pressure gauge calibration time shall be in every 6 months as per the normal practice and various project specifications. Thanks & Regards, (Karthik) Karthikeyan.S QA/QC Manager Getabec Energy Co.,Ltd. 379,Moo6,Soi8,Nikhomphatana, Rayong-21180, Thailand. Phone: 0066 38 897035-8 (Off) Fax: 0066 38 897034 Hand Phone: 0066 892512282 --- On Thu, 11/25/10, Praveen Kumar <praveenkumar.sek@gmail.com> wrote:
|
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.