This clause is applicable when Notch Toughness is required in production welding .
Pl. check the design drawing.
If Design Data is specifying that Notch Toughness Testing 'REQUIRED " then it is required
Pl. check
As per my knowledge , for water station piping , it is not required as low temperature application is not there .
Check the drawing .
On Sun, Aug 30, 2020 at 4:13 PM udaya bhaskar <dusroni@gmail.com> wrote:
Dear Experts,--Please Can you clarify to me the above highlighted point "T limits toughness".This point Where is and when is applicable these Supplementary Essential Variables in WPS.
Will This Clause be applicable in water station piping WPS at Gulf countries?
Material : API5L-PSL2--With RegardsUdaya bahaskar.D+919676270121
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CANii3ROgt2d1_hs8pgoZqKd5EUjgd7quAqH8h-8z%2BnBfr2%3Dd0A%40mail.gmail.com.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CADder3NOR65DFbjfVQEvUi7d_CPTaOO%3DM09wX6mbtjr0OGop_w%40mail.gmail.com.
No comments: