Monday, August 17, 2020

Re: [MW:31312] Pre heating as per ASME SEC I / VIII DIV I

specified thickness. ref iso 15614-1

THANKS & BEST REGARDS,
KG.PANDITHAN, BE, IWE,  CSWIP 3.1,
ISO 9712 Level 2 in VT,
ASNT-Level II in PT,MT,RT & UT,
LA ISO 9001-2015,
International Welding Engineer. 
CONSULTANT-WELDING & QUALITY
Mobile no: +919940739349


On Mon, Aug 17, 2020 at 9:56 AM Vishwas Keskar Welding Manager WELDING <vvkeskar123@gmail.com> wrote:

Specified thickness of the Pipe is 12.7 mm 
Actual thickness measured is 13mm 

Client specified preheating for  12.7 mm (=/>) =75 Deg C

Is preheating is to be decided on specified thickness or  actual thickness?
Any Construction Code back up >


--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/23337554-0c50-46b4-911c-5fdac2322672n%40googlegroups.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAJzm4eM1wbOsLdH5M51nQ88fs7dEoGzXMQCs-oCKo9dK7-_NYQ%40mail.gmail.com.

No comments:

Re: [MW:35354] Cast-iron welding

1. Preheat joint area(other area, cover with mineral wool). 2. ENiCi or ENiFe-CI. 3. stringer bead. 4. peening is to be done on weldmetal im...