Dear Experts,
Iam sandeep.Raghavan. Iam Writing this E-Mail in relation with the Confusion that I am Facing regarding the Changes in AWS D1.1: 2020 compared to 2015 Edition.
In AWS D1.1:2015, Table 4.5, Point No.27(General), It is mentioned as , A Change in position not qualified by Table 4.1 or 9.9 which are range of qualifications for Welding position for Welding Procedure in Plates & Tubular Sections Respectively.
But as it Comes in AWS D1.1:2020, The table is replaced by Table 6.5 which mentions , A Change in position not qualified by Table 6.1 or 6.10. Again 6.1 is equivalent to 4.1. But 6.10 is for Welder & Welding operator Qualification Requirements. As per this clause, I feel Contradictions.(For Eg: 3G qualifies only Vertical as per 6.1 & Flat, Horizontal & Vertical as per Table 6.10). I believe this must be a Typo Error.
Also In AWS D1.1:2015, for CVN Requirements, 3G Vertical qualifies all position(Table 4.6, Point 6). But the same clause is missing in AWS D1.1:2020.
Please clarify my above queries.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/39352337-ebfb-45e0-b42b-8ac851318d30o%40googlegroups.com.
No comments: