You can proceed and no new PQR to be qualified.
Thanks & Regards
VV, Qatar
On Mon, Aug 17, 2020, 15:16 Gowtham Rajendran <rajgowthamiwe@gmail.com> wrote:
Dear All,--I have a doubt from ASME Sec. IX as mentioned below , please clarify.Welding Process : SMAWElectrode used in PQR : E7018-1 (Kiswel)Toughness Test : ApplicableSo as per Table (QW-253) - QW 404.12 is supplementary essential variableElectrode available Now : E7018-1 H4 (Oerlikon) & this has to be used in production now.Suggest whether the manufacturer of welding consumable can be changed with same electrode classification or new PQR has to be Qualified.