Dear Ilkin,
If the "leg size" is 5mm then the throat is 3.5mm and you end up with 21+3.5=24.5 mm
In these calculations the throat of the fillet weld should be taken into consideration and not the leg size.
Regards
Ramin Kondori
Sr. QA/QC & Welding Engineer
-----------------------------------------------------------
PG-Dip. in Welding Engineering (IWE AT 0070)
BSc. in Civil Engineering (IUT)
BGAS Painting Inspector
ASNT Level I&II
On Wed, May 13, 2020 at 3:31 PM Ilkin Hasanov <ilkinhasanov.91@gmail.com> wrote:
Hi Gents,--
We have a partial penetration (S=21mm) with 5 mm leg length joint configuration ; (Tee Joint - combination weld (partial pen + fillet weld)
As per Client requirements if reference thickness is more than 25mm NDT should performed after 48 hours. (Reference thickness is
Could you please advise in our case what is the reference thickess 21 or 26 mm (21mm+5mm)
Regards,
Ilkin Hasanov.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CADrxeDYx_%3DoAOWk_S4Swb7CzdC9zWF%3DTEHEbhorJzb8QiZG6Hg%40mail.gmail.com.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAEagfUjmasXhOT3eXhwrUh0rmZrSOVUMtmzcN4sOdAwY%3Dm7mZw%40mail.gmail.com.
No comments:
Post a Comment