Tuesday, May 26, 2020

Re: [MW:30913] Ferrite No 7 to 8

Dear sir, API 582 defines range of FN 5.

Again it's based on fabrication influence on welded part checking.

Regards

Dinesh

On Tue, May 26, 2020, 08:50 Vinay Thattey <vinay.thattey@gmail.com> wrote:
Dear Friends ;  For some technical reasons the expected ferrite   after completion of circumferential welding for SS to SS ( ASTM-A -240 SS 316 rolled pipe )  is 7 to 8 . We R using 308L / 316 L filler and obtained result is max 5 . pl advice .

--