Hi !
Liner attachment.is not accepted by designer ( Ask licensor)
You require to have a metallurgical bonding by carrying out overlay welding
90:10 Cu Ni.is compatable with C S
Regards
Hegde
-- On Mon, 4 May 2020 at 16:50, Baha<b.nikrooz@gmail.com> wrote:The application of blind flange (ASTM A105+CUNI 90/10 cladding) is for sea water--
On Sunday, May 3, 2020 at 12:03:43 PM UTC+4:30, Vinay wrote:Application ??On Sat, 2 May 2020 at 13:55, Baha <b.ni...@gmail.com> wrote:Hi--Is it acceptable to use plate instead of cladding for blind flange? The cladding material and plate is CU NI 90/10.The below drawing is the manufacturing offer.
https://materials-welding. blogspot.com/
https://www.linkedin.com/ groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to material...@ googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/ msgid/materials-welding/ 3612b777-edba-433e-8658- cf93bc126f3d%40googlegroups. com.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/665ec29e-8f34-43ab-a44e-9a218ae7d23b%40googlegroups.com.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/973084123.1059487.1588671586455%40mail.yahoo.com.
No comments:
Post a Comment