Monday, October 28, 2013

[MW:19087] ASME SECT IX-QW-405-Clarification Required

Dear Experts


ASME IX- Weld Position Qualified Range- Neither Essential/or Supplementary Variable- Confused in understanding the range qualified in Struture and Pipe Weld Positions.

 Pls explain in detail with some tabulation/reference to Code Interpretations:-

 1 -QW-405.2-PQR qualified in 3G( Plate)  position qualify for:-
       1.1  1G,2G,3G,4G,and 6GR -Structure as well?
       1.2   1G.2G.5G.6G - Piping
This is applicable  only when CVN Test Required?

 How about when a PQR qualified 3G without CVN Test?

2 - Can i qualify PQR in 3G Position(Plate) tests done meeting ASME Sect IX and use for Structural welding?

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...