Wednesday, October 30, 2013

[MW:19127] API 1104

Dear
I use on site as welding process  is GMAW automatic machine as 1104 and so my  qestion can I repair the defects if it discovered during RT by using SMAW manual and for knowlage smaw as wps and PQR are qualified   .
regards

No comments:

[MW:35536] RANGE ASME SEC IX

Dear All we have qualified WPS for ( ASME SEC IX) 1. BASE plate 8 mm ( 8TO 16 mm RANGE WITH IMPACT )  2 . BASE plate 25 mm ( 16TO 50mm RANGE...