1st you mention construction code which applicable if ASME B31.3-2008 then see Table 341.3.2 Acceptance Criteria for Welds and Examination Methods for Evaluating Weld Imperfections
as per this
L Height of reinforcement or internal protrusion [Note (8)] in For T w, mm (in.) Height, mm (in.)
any plane through the weld shall be within limits of
the applicable height value in the tabulation at right, ≤ 6 (1⁄4) ≤ 1.5 (1⁄16)
except as provided in Note (9). Weld metal shall merge > 6 (1⁄4), ≤ 13 (1⁄2) ≤ 3 (1⁄8)
smoothly into the component surfaces. > 13 (1⁄2), ≤ 25 (1) ≤ 4 (5⁄32)
> 25 (1) ≤ 5 (3⁄16)
M Height of reinforcement or internal protrusion [Note (8)] Limit is twice the value applicable for L above
as described in L. Note (9) does not apply.
so and same like API 1104 have criteria
 


On Mon, May 27, 2013 at 9:28 AM, Dominic v.k.dominic <v.k.dominic@gmail.com> wrote:
Dear Expertise,

I have this issue please anyone clarify me,
One QA/QC- Inspector 20 years Experience person  he rejected one 24" pipe line  RT film   because of excessive penetration by measuring the dimension with a ruler and required the joint to be repaired..
This is Acceptable or Not Acceptable.
if Acceptable where is mentioned the code?
Please clarify me, Because my management take this issue very serious  

Best Regards 
Dominic V.K.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
 
 



--

Regards

BABUR KHAN LASHARI

Welding Inspector

(QA/QC)

SATORP (JERP)

Mob: +966 (0) 56 2179280

         +92334 6186285  

Skype Id : babur.lashari

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
 
 

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...