Hi, 

Contrast, definition, detail etc. are qualitative(can not be measured) term , whereas, Density is a quantitative (can be measured) term.

Following is the extraction from www.ndt-ed.org , which may be helpful to you.

Radiographic contrast describes the differences in photographic density in a radiograph. The contrast between different parts of the image is what forms the image and the greater the contrast, the more visible features become. Radiographic contrast has two main contributors: subject contrast and detector or film contrast.

Subject contrast is determined by the following variables:
- Absorption differences in the specimen
- Wavelength of the primary radiation
- Scatter or secondary radiation

Film contrast is determined by the following: 
- Grain size or type of film
- Chemistry of film processing chemicals
- Concentrations of film processing chemicals
- Time of development
- Temperature of development
- Degree of mechanical agitation (physical motion)

Exposing the film to produce higher film densities will generally increase contrast. In other words, darker areas will increase in density faster than lighter areas because in any given period of time more x-rays are reaching the darker areas. Lead screens in the thickness range of 0.004 to 0.015 inch typically reduce scatter radiation at energy levels below 150, 000 volts. Above this point they will emit electrons to provide more exposure of the film to ionizing radiation thus increasing the density of the radiograph. Fluorescent screens produce visible light when exposed to radiation and this light further exposes the film.
 
 
 Definition
Radiographic definition is the abruptness of change in going from one density to another. There are a number of geometric factors of the X-ray equipment and the radiographic setup that have an effect on definition. These geometric factors include:
- Focal spot size, which is the area of origin of the radiation. The focal spot size should be as close to a point source as possible to produce the most definition.
- Source to film distance, which is the distance from the source to the part. Definition increases as the source to film distance increase.
- Specimen to detector (film) distance, which is the distance between the specimen and the detector. For optimal definition, the specimen and detector should be as close together as possible. .
- Abrupt changes in specimen thickness may cause distortion on the radiograph.
- Movement of the specimen during the exposure will produce distortion on the radiograph.
- Film graininess, and screen mottling will decrease definition. The grain size of the film will affect the definition of the radiograph. Wavelength of the radiation will influence apparent graininess. As the wavelength shortens and penetration increases, the apparent graininess of the film will increase. Also, increased development of the film will increase the apparent graininess of the radiograph. 

Nandeesh


From: Mohamed Motawea <eng.motawea@gmail.com>
To: Materials & Welding <materials-welding@googlegroups.com>
Sent: Tuesday, 29 November 2011 3:12 PM
Subject: [MW:13095] Re: contrast of film radiographic

Dear sir;
  There is differnec between the film contrast and film density.

Regards;
Mohamed

On Nov 29, 10:43 am, yogeshkumar Kumbhar <kumbharyoge...@gmail.com>
wrote:
> Dear Mehdi,
>
> Measure radiography film contrast ( Density ) by densitometer.
>
> Regard's
>
> Yogesh V Kumbhar
>
>
>
> On Tue, Nov 29, 2011 at 10:21 AM, Mehdi Emami <mehdi.em...@yahoo.com> wrote:
> > Dear experts
> > Can anyone tell me how to measure contrast of radiographic films?in fact,
> > I want Definition  & contrast calculation method
> > Thanks
>
> > --
> > To post to this group, send email to materials-welding@googlegroups.com
> > To unsubscribe from this group, send email to
> > materials-welding+unsubscribe@googlegroups.com
> > For more options, visit this group's bolg at
> >http://materials-welding.blogspot.com/
> > The views expressed/exchnaged in this group are members personel views and
> > meant for educational purposes only, Users must take their own decisions
> > w.r.t. applicable code/standard/contract documents.- Hide quoted text -
>
> - Show quoted text -

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...