Monday, April 19, 2010

Re: [MW:0] Acceptability of MTC.

Since this job according to ASME, as per ASME section II part A Copper content is not designated, So this MTC is not acceptable,Refer ASME sec-II -page 753.
 
V.Ravishanker



From: smruthi mohan <smruthi2007@rediffmail.com>
To: materials-welding@googlegroups.com
Sent: Sun, 18 April, 2010 4:59:36 PM
Subject: [MW:4854] Acceptability of MTC.

Hi.

Anybody please advise me on the below,

we have an 12" End Cap (SA403 WP316L)for an ASME job. But in test certificate there is an additional element content (Cu (0,370))is present in the chemical Analysis. please advice me that we can accept this item or not.

Thanks in advance.

SMRUTHI MOHAN
ENGINEER - MATERIALS.
QICL, FUJAIRAH

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34920] Tubesheet Hole step