it is acceptable .
On Thu, May 7, 2015 at 5:24 AM, Eric.C <ericheng87@gmail.com> wrote:
Hi All,--Mill performed ET for 1.5" Sch160 Smls Pipe A333 Gr.6.Is ET acceptable in lieu of hydrotest? if yes, is there any limitation criteria?Thanks.Regards,Eric.C