Hi All,
-- Mill performed ET for 1.5" Sch160 Smls Pipe A333 Gr.6.
Is ET acceptable in lieu of hydrotest? if yes, is there any limitation criteria?
Thanks.
Regards,
Eric.C
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/725e2e6d-7969-4d55-ab84-a02452545612%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.
No comments:
Post a Comment