Hi!
Why do you want to Normalise the component after Overlay generaly No normalsing is reqd on Overlayed component
Regards
Hegde
On Friday, 16 May 2014 4:09 PM, Jimmy Taylor <drums4tay@gmail.com> wrote:
Hi all!
-- This is my first post, so please excuse my etiquette if improper. I'm sure I will learn as I go.
Question: What is the effect on say (14"NPS x .500wall SA-106B-N) if I were to clad the inside with 1 layer of 309L and 2 layers of 316L via SMAW? I'm particularly interested in the effect the HAZ will have on the Normalization of the material.
Thanks in advance!!
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.