Dear Nishant
-- Hydrotest pressure is code specific. As per IBR and ASME B31.1, it is 1.5 times the design pressure, howver as per ASME B31.3., it is MINIMUM 1.5 times the design pressure and a provision of temperature correction factor has to be multiplied when hydrotesting High pressure piping
Regards
Arunabh
Engineers India Limited
On Saturday, April 27, 2013 4:32:02 PM UTC+5:30, nishant wrote:
Engineers India Limited
On Saturday, April 27, 2013 4:32:02 PM UTC+5:30, nishant wrote:
Why hydrotest pressure is taken 1.3 times of design pressure? What is the criteria that fixes the term 1.5 times or 1.25 times, etc.???
Thanks in advance,
Nishant nair
Sent from Yahoo! Mail