Dear Experts,
please share your valuable inputs for the below query:
background:
I have done a PQR with charpy impact applicable for that material.
Plate thickness: 20 mm, in which groove made to 13 mm and is welded. (Refer figure 1)
This PQR test weldment is subjected to PWHT as Normalize + quench and tempered.
Figure:1
This allows range qualification as per QW 451.1 with base material to 5-22 mm and weld metal up to 26 mm.
Query:
- Can I use WPS with the thickness range qualified (PQR) as above for a repair of casting (as shown in the figure 2) having thickness 40 mm and excavation to deep 20 mm.
Figure 2:
- Whether the thickness below excavation is considered as parent metal backing and excavated depth is as base metal thickness?
Thanks,
MANIVANNAN.P
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.
No comments:
Post a Comment