Skip to main content

Re: [MW:20705] ASME SEC IX QW202.1

BEGIN:VCARD
X-LOTUS-CHARSET:UTF-8
VERSION:3.0
PRODID:-//Lotus Development Corporation//NONSGML Notes 8.5.2//EN_C
FN:George H Dilintas/GRC/VERITAS
N:Dilintas;George;;;
ADR;TYPE=WORK;TYPE=PREF:PIRAEUS;;23\, Etolikoy Str.;PIRAEUS;;185 45
;GREECE
ADR;TYPE=HOME;TYPE=PREF:;;19-21 B. Laskou str.;Athens;Attika;11 633
;Greece
TEL;TYPE=HOME:+30-1-7667 197
TEL;TYPE=WORK:+30-210-40 63 113
TEL;TYPE=HOME;TYPE=FAX:+30 - 1 - 7667 197
TEL;TYPE=WORK;TYPE=FAX:+30-210-40 63 118
TEL;TYPE=CELL:+30 -69 44-64 62 04
EMAIL;TYPE=WORK;TYPE=PREF;TYPE=INTERNET
:george.dilintas@gr.bureauveritas.com
ORG:Bureau Veritas;Industry
REV:20131201T024559Z
END:VCARD

I disagree
Please read carefully: It is written in the 1st paragraph of QW 202.1 "If any test specimen required by QW-451 fails to meet the applicable acceptance criteria, the test coupon shall be considered as failed"

    best regards

    Dr. Georgios Dilintas

    Authorized Nuclear Inspector
    Authorized Inspector Supervisor
    API 510 Inspector

    I&F REGIONAL TECHNICAL MANAGER
    BUREAU VERITAS HELLAS

    Tel: +30 210 40 63 113/4
    Fax: +30 210 40 63 118
    Cell: +30 69 44 64 62 04
    (See attached file: Dilintas_George.vcf)

meisam shokri arfaei ---29/04/2014 15:53:13---Dear Tulasi, 1 new specimen for 1 failed specimen (but just from the same test coupon).

From: meisam shokri arfaei <meisamshokri@gmail.com>
To: materials-welding@googlegroups.com
Date: 29/04/2014 15:53
Subject: Re: [MW:20695] ASME SEC IX QW202.1
Sent by: materials-welding@googlegroups.com




Dear Tulasi,

1 new specimen for 1 failed specimen (but just from the same test coupon).

Regards 


On Tue, Apr 29, 2014 at 10:36 AM, SWI <tulasiramus@gmail.com> wrote:
    Thanks for the info,

    Please note that QW202.1 also allows for retesting ( after considering all ifs & buts in the code/ QW153) from the same test coupon. Now my question is, if one tensile specimen fails, how many additional test specimens shall be tested.

     

    On Monday, April 28, 2014 2:41:28 PM UTC+3, sina wrote:

    Dear friend,

    If any specimen fails to meet the requirements, the test coupon consider to be failed and a new test coupon shall prepare. (It could be with the same parameters or changed parameters)

    Regards


    On Mon, Apr 28, 2014 at 10:46 AM, STR <tulas...@gmail.com> wrote:
      Friends,

      Good Morning,

      With reference to ASME Sec IX:

      1. If one tensile specimen failed the requirement of QW153
      2. How many additional specimens are to be tested QW202.1


      Regards,
      Tulasi Ram

      --
      To post to this group, send email to material...@googlegroups.com
      To unsubscribe from this group, send email to materials-weld...@googlegroups.com


      For more options, visit this group's bolg at
      http://materials-welding.blogspot.com/
      http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
       
      The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
      ---
      You received this message because you are subscribed to the Google Groups "Materials & Welding" group.

      To unsubscribe from this group and stop receiving emails from it, send an email to materials-weld...@googlegroups.com.

      For more options, visit
      https://groups.google.com/d/optout.




    --
    M. Shokri Arfaei

    ISA-ISTS - Metallurgy Lab. Manager
    ASNT NDT Level III
    International Welding Engineer

    Tel.: +98 21 66282127
    Fax: +98 21 66282779
    Mob.:+98 912 1394023



    --
    To post to this group, send email to
    materials-welding@googlegroups.com
    To unsubscribe from this group, send email to
    materials-welding+unsubscribe@googlegroups.com
    For more options, visit this group's bolg at
    http://materials-welding.blogspot.com/
    http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
     
    The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
    ---
    You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
    To unsubscribe from this group and stop receiving emails from it, send an email to
    materials-welding+unsubscribe@googlegroups.com.
    For more options, visit
    https://groups.google.com/d/optout.




--
M. Shokri Arfaei

ISA-ISTS - Metallurgy Lab. Manager
ASNT NDT Level III
International Welding Engineer

Tel.: +98 21 66282127
Fax: +98 21 66282779
Mob.:+98 912 1394023



--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm

The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to
materials-welding+unsubscribe@googlegroups.com.
For more options, visit
https://groups.google.com/d/optout.

This message contains confidential information. To know more, please click on the following link: http://disclaimer.bureauveritas.com

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...