You certainly know that in ASME IX the base metal thickness and the deposited metal thickness are two different essential variables.
When you want to support a WPS by means of a PQR you have to satisfy all essential variables by means  of the qualification ranges.
The Code, with QW-200.4 (b) offers a flexibility regarding the base metal thickness but for the root passes only
So if you have a base metal thickness of let us say 50 mm, you may base you WPS, for the root passes only, on a PQR done with a test coupon of 13 mm, although the 13 mm qualify base metal thickness only up to 26 mm.
For the other passes you need however a PQR based on a specimen thickness of 25 mm minimum
I hope I helped....

    best regards

    Dr. Georgios Dilintas

    Authorized Nuclear Inspector
    Authorized Inspector Supervisor
    API 510 Inspector

    I&F REGIONAL TECHNICAL MANAGER
    BUREAU VERITAS HELLAS

    Tel: +30 210 40 63 113/4
    Fax: +30 210 40 63 118
    Cell: +30 69 44 64 62 04
    (See attached file: Dilintas_George.vcf)

Vicky Patil ---16/04/2014 15:57:01---i ready minimum 13mm for each single process for combination of 2 PQR i am true ya wrong ??

From: Vicky Patil <patilvicky4@gmail.com>
To: materials-welding@googlegroups.com
Date: 16/04/2014 15:57
Subject: Re: [MW:20598] Combination of Two PQRs
Sent by: materials-welding@googlegroups.com




i ready minimum 13mm for each single process for combination of 2 PQR i am true ya wrong ??

please reply 


On Sat, Apr 5, 2014 at 6:40 AM, Raghuram Bathula <raghurambathula@gmail.com> wrote:

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm

The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to
materials-welding+unsubscribe@googlegroups.com.
For more options, visit
https://groups.google.com/d/optout.

This message contains confidential information. To know more, please click on the following link: http://disclaimer.bureauveritas.com

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone