Our client requirement states that Stress Relieving of Titanium U bends is mandatory. Our Metallurgy of Tubes is SB 368 Gr. 2 (UNS R50400)
Tube side fluid is sea water and Shell side fluid is sour gas (172 bar Pressure and 170 deg cel at shell side)
In view of above , please let me know , Is it really require to perform SR of Titanium U bends.
NACE states that Titanium is susceptible to Stress corrosion cracking. Vendors are not in opinion of doing SR.
Please provide your valuable input
Thanks
Ashish
-- Tube side fluid is sea water and Shell side fluid is sour gas (172 bar Pressure and 170 deg cel at shell side)
In view of above , please let me know , Is it really require to perform SR of Titanium U bends.
NACE states that Titanium is susceptible to Stress corrosion cracking. Vendors are not in opinion of doing SR.
Please provide your valuable input
Thanks
Ashish
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.