If you are particular about impact retirements, then AWS SFA 5.5 E 8018 - C1
could be used. Similarly SFA 5.28 ER 80 Ni2 is recommended for root pass in TIG process.
If impact is not a criteria, then, SFA 5.18 ER 70 S-6 can be used for root and
SFA 5.5 8018 / E8018-C1 for filler & cap.
From: "rhmalhotra84@gmail.com" <rhmalhotra84@gmail.com>
To: materials-welding@googlegroups.com
Sent: Sunday, 13 April 2014 8:43 PM
Subject: [MW:20578] Suitable electrode for SAE 4130 Pipe
Dear Experts,
Could you suggest me suitable and weldable electrode and its sfa/aws no. for Pipe SAE 4130 material.
Rgds,
Rohit
----------
Sent from my Nokia phone
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.
Comments