They do not meet the requirements of B16.5 as far as the dimensions are concerned. They may not meet also the temperature / pressure ratting since the cladding process may alter the flange properties.
The dimensional issue is not a problem. The manufacturer has to provide evidence that the cladding process has not altered the temperature/pressure ratting

    best regards

    Dr. Georgios Dilintas

    Authorized Nuclear Inspector
    Authorized Inspector Supervisor
    API 510 Inspector

    I&F REGIONAL TECHNICAL MANAGER
    BUREAU VERITAS HELLAS

    Tel: +30 210 40 63 113/4
    Fax: +30 210 40 63 118
    Cell: +30 69 44 64 62 04
    (See attached file: Dilintas_George.vcf)

Josnit ---29/04/2014 15:22:54---Dear Experts, We have fabricated one vessel as per ASME Section VIII Div. 2 Edition 2010,

From: Josnit <nithindsilva4u@gmail.com>
To: materials-welding@googlegroups.com
Date: 29/04/2014 15:22
Subject: [MW:20694] RF of ASME B16.5 Flanges
Sent by: materials-welding@googlegroups.com




Dear Experts,

We have fabricated one vessel as per ASME Section VIII Div. 2 Edition 2010, Add. 2011. The vessel is internally cladded with Alloy 625 for corrosion resistance purpose. Cladding thickness is not considered in the design. The flanges were ordered as flat face and corrosion resistance overlay was applied, and machined to RF required dimensions as per ASME B 16.5. Reference to the attached interpretation, when the RF was made with different material (corrosion resistance cladding), does these flanges are categorized as non standard flanges?? Please give your opinion on the same.

Regards,

Josnit

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm

The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to
materials-welding+unsubscribe@googlegroups.com.
For more options, visit
https://groups.google.com/d/optout.[attachment "Interpretation 11-3.pdf" deleted by George H Dilintas/GRC/VERITAS]

This message contains confidential information. To know more, please click on the following link: http://disclaimer.bureauveritas.com

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone