Friday, January 25, 2013

Re: [MW:16598] Linier indications observed in Radiography Testing in SA240 310S weld

control interpass less than 150 degree celcius, heat input( use heat sinkers)
Pandithan
Welding Consultant

On Wed, Jan 23, 2013 at 4:41 PM, mukesh.chaudhari <mukesh.chaudhari@orientalindia.net> wrote:

Dear Expert,

We are doing SA240 Type 310s material welding with WPS(GTAW) but there are lot of defects of linier indications(micro cracks) observed in Radiography testing.

We are using D&H make ER-310 filler wire for welding. We also preheat the joint up to 80 °C to avoid sudden cooling.

Can you guide me how to avoid linier indications(micro crack) in welding.

 

Regards,

Mukesh

 

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone