Friday, December 21, 2012

Re: [MW:16289] Re: EN287-1, welder Qualification

Dear All,
Thanks.My doubt is , can the radiographically unintrepretable joint be qualified by replacing the fracture tests by 2 Nos. Macro only?
Thanks and Best regards,
K.Rajagopal


On Fri, Dec 21, 2012 at 10:26 AM, B R Meghwal <br.meghwal@fernas.co.in> wrote:

Dear Mr. Rajagopal,

 As we well aware, we have to accomplish the requirement of standard/code.  As per interpretation of EN287-1 code, If you have to replace fracture test with macro then only 2 macro sections are enough with one of them in start, stop points.

Thanks & regards,

B.R.Meghwal
Dy. Manager-QA/QC & NDT Level III

fernas logo

FERNAS Construction India Pvt. Ltd.

(A wholly owned Subsidiary of FERNAS Construction Company Inc., Turkey)

Cyber Terrace, 16th Floor, Tower – B, Building No. 5, DLF Cyber City, Phase – 3

Gurgaon – 122 002, Haryana, INDIA.

(: +91 124 4937984       (M) : +91 8860651934

Life is not about what you couldn’t do so far, It’s about what you still can...........

image002Lütfen bu e-postayı yazdırmadan önce çevrenizi düşünün. | Before printing this e-mail ask yourself: "Do I need a hard copy?"

Confidentiality Notice

This e-mail and the accompanying document(s) contain confidential information which is privileged and intended only for the addressee here of. If you are not the intended recipient, you are here by notified that any disclosure, copying, distribution or use of this e-mail and/or accompanying document(s) is strictly prohibited. If you have received this e-mail in error, please immediately notify the sender at the above e-mail address.



On Sunday, 16 December 2012 14:26:07 UTC+5:30, Rajagopal wrote:
Dear All,
 
Kindly help me in interpretation of EN287-1 code.
The tests required for a fillet weld qualification in table -1, which says fracture test according to EN 1320 is mandatory, with reference to 2 foot notes, Viz. c and e.
Foot note c. The fracture tests may be replaced by a macroscopic examination according to EN1321 of atleast two sections.
Foot note e. The fracture tests on pipes may be radiographic testing.
 
Our test piece is Pipe to Plate Fillet weld.
 
Now, for this joint, Radiography is not possible. If we have to replace fracture test, will it be enough if we go for only 2 macro sections  with one of them in start, stop points?
 
Kindly advise me.
 
Thanks and Best Regards,
K.Rajagopal

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...