Friday, December 21, 2012

Re: [MW:16300] Re: E7016 vs E6010


Further to Sridhar, attached are the 2 files of ESAB. You can decide yourself and chose that best suits you.

ವಂದನೆಗಳೊಂದಿಗೆ / Best regards,

Nandesh Kumar A

Abu Dhabi, UAE

P.S. : Please don't print this e-mail unless you really need to.


--- On Fri, 21/12/12, c sridhar <sridhar305@yahoo.com> wrote:

From: c sridhar <sridhar305@yahoo.com>
Subject: [MW:16294] Re: E7016 vs E6010
To: "ABHISHEK GHOSH" <ghoshabhishekmech@gmail.com>, "materials-welding@googlegroups.com" <materials-welding@googlegroups.com>
Date: Friday, 21 December, 2012, 11:30 AM

Mr. Abhisekh,

Pl.refer to your mail and the reply as follows:


Impact tested at ( -40)  deg C

a. Both electrodes  do give good impact results only up to - 29 (E 6010) and -30 (E 7018) deg.C. only.
 
My Question is in refinery piping B31.3, pipeline ,  in root welding ( CS)  I have used E6010 . Which one is superior between E6010 & E 7016 -1 H4R for root runs & why ?? please elaborate.
 
a.     E 6010 is a deep penetration type electrode ( avg. penetration  of 2.00 2.50 mm) and well suitable for root  run in
        small/medium bore  pipes there is no accessibility for repair welding, but Not for F/C  due to rough arc nature.
       The Hydrogen content is > 30 ml. of H2 per 100 grams of weld metal. Balnce runs are by E 6013 / E 7018 or so.

a.1   E 7016H4 R (or) E 7018 H4 R electrodes are not to be compared with E 6010.Both electrodes are to be compared
        to & much superior to  E 7016 & E 7018 respectively, in the sense, the weld metal has much longer life than the
        weld metal deposited with normal type basic electrodes, due to its lower impurity levels.
a.2.  While  the Hydrogen content is < 15 ml. of H2  per 100 grams of weld metal in E 7018 & E 7016, it is much lower in
        E 7016H4 R & E 7018 H4 R electrodes. i.e., The H2 level is <4 ml/100 grams of weld and typical values are < 1.9 to
        2..0 ml only ( measured in accordance with AWS/ANSI 4,3-86) specifications..
a.3.  That means while normal basic electrodes to be dried at 300 deg.C prior to use, H4R  type electrodes do not
        require  any re-drying at ll. They are vacuum packed and could be used straight on the job.
a.4   All the electrodes are medium penetrate type and could be used for Root and F.C passes.
a.5.  E 7016 / 7016 H4R gives more root penetration  with DCEN  compared to DCEP and E 7018/H4R as they are used
        with  DCEP only. 

Sridhar.
-----------------------------------------------------------------------------------------------------------------------------------------------------
From: ABHISHEK GHOSH <ghoshabhishekmech@gmail.com>
To: pgoswami <pgoswami@quickclic.net>; c sridhar <sridhar305@yahoo.com>; John Henning <jhenning@deltak.com>
Sent: Thursday, 20 December 2012 9:09 AM
Subject: E7016 vs E6010

Dear Experts, 
In our Structural Deck( Cellar, Mezannine )  Construction ( AWS D1.1) , we are using WPS of   E 7016-1 H4 R  ( root ) & Remaining passes with E 7018 H4 R & E 71T - 1 .
Material : API 5L 2W, AI 5L X52 ( AWS D1.1 - Group II)
Thickness range in WPS  : 8- 65 mm
Preheat : upto 38 mm = 30 deg C  , 38- 65 mm = 65 deg C
Impact tested at ( -40)  deg C
groove details :  X bevel , K bevel, 1/2 Bevel etc.
Gouging : Air Arc / grinding.  
 
My Question is in refinery piping B31.3, pipeline ,  in root welding ( CS)  I have used E6010 . Which one is superior between E6010 & E 7016 -1 H4R for root runs & why ?? please elaborate.
 
Thanks & regards.
Abhishek Ghosh
Indonesia

 
 


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

No comments:

Re: [MW:34935] Re:

Dear sir , Can you share references/Documents  @ james Gerald ?  On Mon, Apr 29, 2024 at 9:11 PM 'james gerald' via Materials & ...