The laboratory was right. You can refer the appendix of A333 which made an example for these cases. Totally the 3C reduction is right.
Regards
--
-- On Sat, Dec 29, 2012 at 10:47 AM, Farhang <hyperm2m@gmail.com> wrote:
Dear All
--
I need to know way of calculation temperature reduction when we use sub size specimen.
My problem:
I have tested an A333 Gr.6 (4" pipe-6.3 mm thickness). Labratoary used a sub size specimen (55*5*10). and they tested it in -48c. test temperature of A 333 Gr.6 is -45C and they tested it in 3c cooler temperature Unfortunately absorbed energy was low and my test failed.
But i see a clause in standard(SA-333/SA-333M) which described that:
" 14.1.2) When sub size Charpy impact specimens are used and the width along the notch is less than 80% of the actual wall thickness of the original material "
Is this clause applicable for my case??????
Really i don't know which one is correct?
- (5/6.3) * 100 = 79% then i should not apply the above mentioned clause and i shall calculate reduction temperature and test my sample in cooler temperature(-45-3=-48).
- (10/6.3) * 100 = 159% then i should not apply the above mentioned clause and no need to reduction temperature and test my sample in MDMT(-45).
** In the above text i use different color for digits because you can trace them easier.
Many Thanks
Farhang
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
M. Shokri Arfaei
International Welding Engineer (IWE)
ASNT NDT Level III
ISA - STRI - Metallurgy Lab. Manager
Tel: +98-21-66282127
Fax: +98-21-66282779
Please don't print this e-mail unless you really need to. BeGreen!
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments:
Post a Comment