[MW:3358] Re: Heat Input

E6010 will support up to -29 degree celcius only and used in pipe line root application. But if the PQR passes the impact you can use it with batch restriction.
regards,
Ibrahim

2009/9/29 BHARAT GOLE <bharatgole@hotmail.com>
E 7018-1 is acceptable up to -46 degree but selection E 6010 is not suitable for LTCS ! As per which clause it is selected for LTCS ?

Regards

Bharat B. Gole

 






Date: Tue, 29 Sep 2009 09:49:23 +0530
From: nach_sam@yahoo.com
Subject: [MW:3354] Re: Heat Input
To: materials-welding@googlegroups.com

Adi,
Heat input is a guideline for subsequent welding. The yardstick is the average  value as obtained from your PQR. Your production welding should not exceed PQR HI values.
By the way, is 6010, 7018-1 Ok for LTCS?  What is the working temp?
Shashank Vagal

--- On Tue, 29/9/09, Adi <adinraos@gmail.com> wrote:

From: Adi <adinraos@gmail.com>
Subject: [MW:3352] Heat Input
To: "Materials & Welding" <materials-welding@googlegroups.com>
Date: Tuesday, 29 September, 2009, 9:35 AM



I have done the PQR for LTCS by using 6010 & 7018-1 as per ASME SEC IX
some time i got 5KJ heat in put
What is the limitation for heat input and where it is mention?

Adi


From cricket scores to your friends. Try the Yahoo! India Homepage!</a



Get easy photo sharing with Windows LiveT Photos. Drag n' drop





--
Thanks & Regards
Muhammed Ibrahim PK

--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

[MW:36169] Cold Bending Qualification

Dear Experts,  Can anyone share the inspection requirements or a qualification procedure for cold bending? Our client spec states only the requirements for induction bending and would like to know your opinion on the cold bend inspection requirements. The code of construction is B31.3, Max. 5D bends, A106 SS 316L.  Thanks in Advance. -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/1be61cc3-e9c9-4a5f-834d-e8485e248432n%40googlegroups.com .

[MW:30043] Weep hole

If weep hole is not provided in dummy pipe before welding What will happen??? -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/da251ee6-fa7f-4851-b876-cdb3834ae341%40googlegroups.com .