RE: [MW:4834] Radiographic film interpretation

As per ASME section VIII Div 1 Appendix 4 clause 4-3 Density within image of the indication may vary and is not criterion for acceptance or rejection.
However acceptance or rejection will be  based on size, spacing, concentration and type of indication etc.

If indication is conformed as  LOF as per UT apart from  20% DAC then its not acceptable as per ASME Section VIII  but certain length of Inter pass LOF is acceptable as per API 1104 So its depend upon code of constrruction.

But there is no creteria for acceptance or rejection based on density difference Only Root concvity & undercuts will be accepted or rejected based on density differnece.

Regards

Bharat B. Gole






Date: Thu, 15 Apr 2010 20:16:46 +0530
From: nach_sam@yahoo.com
Subject: [MW:4850] Radiographic film interpretation
To: materials-welding@googlegroups.com

Hi all,
In one RT film we have a 10-12 mm spot with density 3.13. The weld density is 3.17 and the parent metal density is 3.3. It is apparently interpass LoF in the 2nd fill pass after hot pass (confirmed by UT, where the indication ht is approx 20%of DAC). Is there any or what is the criteria for acceptance/rejection based on density difference?
Rgds,
Shashank Vagal


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


The latest auto launches and test drives Drag n' drop

No comments:

[MW:34919] Welder qualification certificate

Dear All     anyone can share a format for welder certificate and card format        Thanks & Best Regards Saleem manhappulath Mob:+9665...