Friday, January 25, 2019

Re: [MW:28975] SB-209 Grade 5183-PQR failure

Let me send the material certificate by tomorrow.

Regards,
Himan Nikdin

On Jan 25, 2019, at 08:44, Ramin Kondori <raminkondori@gmail.com> wrote:

What is the temper...?

Ramin  Kondori
Sr. QA/QC & Welding Engineer
-----------------------------------------------------------
PG-Dip. in Welding Engineering (IWE  AT  0070)
BSc. in Civil Engineering (IUT)
BGAS Painting Inspector
ASNT Level I&II
                        
IIW-Logo-Colour-small


On Thu, Jan 24, 2019 at 5:01 PM Himan Nikdin <himan.nikdin@outlook.com> wrote:
Dear Experts

A PQR sample has been welded per below procedure;
SB-209 Grade 5183
THK; 40 mm
Process; GTAW
Filer metal; ER5183
Shielding gas; Argon
Preheat Temp; 70°C/Interpass Temp; 100°C
but all four bend samples rejected due to facture, meanwhile the tensile result is less than acceptable criteria.
would you please advise me in regards to the reason for this failure.

Thanks Indeed
Himan Nikdin

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone