Thursday, January 24, 2019

Re: [MW:28967] SB-209 Grade 5183-PQR failure

Check the point of initiation / pattern defects and confirm the fracture locations.

Regards
Muneeb

On Thu, Jan 24, 2019, 8:31 PM Himan Nikdin <himan.nikdin@outlook.com> wrote:
Dear Experts

A PQR sample has been welded per below procedure;
SB-209 Grade 5183
THK; 40 mm
Process; GTAW
Filer metal; ER5183
Shielding gas; Argon
Preheat Temp; 70°C/Interpass Temp; 100°C
but all four bend samples rejected due to facture, meanwhile the tensile result is less than acceptable criteria.
would you please advise me in regards to the reason for this failure.

Thanks Indeed
Himan Nikdin

--