RT done, some porosity observed, but in the acceptable critera per ASME IX. The sample totally broken, it does not seem that the failure occured due to weld defect.
Regards,
Himan Nikdin
First you should do the RT of sample to check if there is any defect in weld or not.
--On Thu, Jan 24, 2019, 7:01 PM Himan Nikdin <himan.nikdin@outlook.com wrote:
--Dear Experts
A PQR sample has been welded per below procedure;SB-209 Grade 5183
THK; 40 mm
Process; GTAW
Filer metal; ER5183
Shielding gas; ArgonPreheat Temp; 70°C/Interpass Temp; 100°C
but all four bend samples rejected due to facture, meanwhile the tensile result is less than acceptable criteria.would you please advise me in regards to the reason for this failure.
Thanks IndeedHiman Nikdin