Hi,
As you are already inlined with the requirements of impact which has been incorporated in procedures clearly saying A 333 Gr 6 and LF2 which is LT, in this case you cannot exempt impact requirements for plates and this is not a non mandatory supplementray requirements but a mandatory requirements which is no waiver between purchase and supplier.
Hence go for Gr 70 LT of A 516 which will be equivalent to in stringent of LF2 which is P1 G2 as similar to 70.
Hope it is comprehended for all.
Thanks.
Regards,
Mohamed Muneeb Mahaboob
CSWIP 3.2-89247/2
IRCA-9001:2015 LA
ASNT-NDT-L2-RTFI-RT-UT-MT-PT.
SAP#:70021650 APs:JAPID, QCS & QCI.
''If you know any art by any means then SCULPT IT - no matter how cheap or useless it is - JUST SCULPT IT, you will never know when experts will be on demand''
please check some points.P number to be sameGroup no to be same ( if impact test )qw 211 plate can be used for pipe and pipe can be used for plate.if impact test applicable than only group no is essential variable--https://materials-welding.blogspot.com/https://www.linkedin.com/groups/122787---You received this message because you are subscribed to the Google Groups "Materials & Welding" group.To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.Visit this group at https://groups.google.com/group/materials-welding.For more options, visit https://groups.google.com/d/optout.