Hi,
Who told you to perform AUT? I mean why not RT? AUT will hold your project in Reverse gear.
Mostly in stringent case we perform AUT/PAUT/TOFD or where there is multiple requirement like tie-in's, anyhow it's mutual agreement between company and contractor.
And yes both are different by 9.3.4 / 9.3.5, ID and IFD, you cannot straight away reject but contemplate upon given para condition as per the pipe sizes then proceed for acceptance/rejections.
Thanks
Muneeb
On Wed, Jan 16, 2019, 9:24 PM Ri@z <riaz.rafeeque@gmail.com> wrote:
--Dear All,Our Pipeline specification not accepting Incomplete Fusion .In case of incomplete fusion weld shall be rejected and re-welded.But according to API 1104, IF and IFD are different . So is it required to reject both IF and IFD as both are incomplete Fusion?Please help me with adviceI am using AUT for the inspection and 70 % of joints are detecting either IF or IFDWith RegardsRiazPls help me
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.
No comments:
Post a Comment