This issue was already dealt with earlier in this forum. Please see the link as below.
Thanks.
P.Goswami.P.Eng, IWE.
Independent Welding & Metallurgical Specialist
· https://groups.google.com/forum/#!topic/materials-welding/gLruDyv4V2Q
From: 'GENE MATSKO' via Materials & Welding [mailto:materials-welding@googlegroups.com]
Sent: January 11, 2019 7:05 PM
To: materials-welding@googlegroups.com
Subject: Re: [MW:28895] Titanium Grade 2 - U tubes - Stress relieving
On Thursday, January 10, 2019 10:56:46 PM CST, Hrushikesh Sangamnerkar <hrushi612@gmail.com> wrote:
Dear experts,
Does Titanium Grade 2 tubes after U bend require any Stress relieving?
If yes then what is the criteria and temp.range?
If no, then what technical backup is there to support it?
--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.
--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.