QUESTION:
Crude oil storage and handling facilities operating at a total absolute pressure below 0.45 MPa. My understanding of the above paragraph is that, it includes only dead oils with no gas in equilibrium. If any gas is in equilibrium with a crude (operating less than 0.45 MPa) which contains H2S more than 0.3kPa (in the gas phase), the whole system is considered as sour. I need your advice for my understanding, if correct or not?


ANSWER:
Crude oil storage and handling facilities means that it is dead oil and H2S/CO2 have been removed. The very low residual amount is considered negligible. This is the reason why these facilities are permitted exclusions from the standard. However, it is up to the user to check that these statements are true for the considered facilities.

Ref# MP INQUIRY #2009-14

https://www.linkedin.com/groups/122787/122787-6419419780360609792

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...