Dear team,
-- Reference to the above mention subject, i would like to know selection of filler wire when welding cladding material for following situation.
1. I have job having below M.O.C for heater bonnet,
CHANNEL PLATE M.O.C - SA 240 GR 304
BODY FLANGE M.O.C - SA 516 GR 70
CLADDING RING M.O.C - SA 240 GR 304
(also find attachment for design joint)
Now my query is on selection of filler wire, can i use following filler wire for above situation
1. ER 309 LMO - It is for root run between body flange and channel plate for above situation.
2. ER 308L - For subsequent layer and final run.
Also can i use wps qualifying with following criteria?.
(see attachment-WPS-1)-For root run welding
(see attachment-WPS-2)-For subsequent & final layer welding.
Or i need to qualify additional wps using two filer wire.
Thanks in advance
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.
No comments:
Post a Comment