Hello,
-- I find it bit strange to receive Ferrite no. above 8 or up to 11 some times, while using FCAW weld overlay on CS surface. What are the reasons behind these.
My requirement is 3 to 8 % only.
Can I have any solution for this ? .
PWHT will be there in my job.
What should I do to restrict up to 8 % only, with same process.
Warm Regards
Purvin Bhatt
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/075922ad-610d-4296-b6a6-b04d12b687e0%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.