Re: [MW:24119] Ferrite No. in Austenistic stainless steel weld overlay in FCAW process

High dilution rate might be a reason

Sent from my BlackBerry 10 smartphone.
From: Bhatt Purvin
Sent: Σάββατο, 16 Ιανουαρίου 2016 - 17:44
To: Materials & Welding
Reply To: materials-welding@googlegroups.com
Subject: [MW:24106] Ferrite No. in Austenistic stainless steel weld overlay in FCAW process

Hello,

I find it bit strange to receive Ferrite no. above 8 or up  to 11 some times, while using FCAW weld overlay on CS surface. What are the reasons behind these. 
My requirement is 3 to 8 % only. 
Can  I have any solution for this ? .
 PWHT  will be there in my job. 
What should I do to restrict up to 8 % only, with same process.  

Warm Regards
Purvin Bhatt 

--